ADA Sign Requirements
A plain-English guide to the signs commercial buildings need under the 2010 ADA Standards: which signs need braille, how they must be made, and where they go.
Which signs need braille and raised text?
Under the 2010 ADA Standards, any sign that identifies a permanent room or space has to be tactile: raised characters plus braille, so someone who is blind can read it by touch. In a typical commercial building that includes:
Room numbers and room names: offices, suites, conference rooms, classrooms
Restrooms, locker rooms, and mechanical, electrical and janitor rooms
Doors to exit stairways, exit passageways and exit discharge
Areas of refuge
Floor designations on elevator hoistway jambs (see below)
Signs that only give directions or information, like "Restrooms →", building rules or hours, must meet the visual rules (readable lettering, contrast, non-glare finish) but don’t need braille. Building directories, addresses, company names and logos, and temporary signs posted for 7 days or less are exempt.
What makes a sign compliant
Raised characters: uppercase, sans serif, raised at least 1/32 inch, and between 5/8 inch and 2 inches tall.
Grade 2 braille: contracted braille placed directly below the text, at least 3/8 inch from it, with rounded dots at standard spacing.
Finish and contrast: a non-glare finish, with light characters on a dark background or dark on light.
Pictograms: symbols such as the restroom figures sit in a field at least 6 inches tall, with the text and braille below the field, never inside it.
Where the signs go
Height: the baseline of the lowest raised line at least 48 inches above the floor, and the baseline of the highest line no more than 60 inches.
Single doors: on the wall beside the door, on the latch side. If there’s no wall there, on the nearest adjacent wall.
Double doors: on the inactive leaf if only one leaf opens; to the right of the doors if both open.
Clear floor space: an 18 × 18 inch clear area centered on the sign and outside the door’s swing, so the person reading it can’t be hit by the door.
Elevator hoistway (jamb) signs
Every elevator entrance needs floor designation signs on both jambs: raised characters at least 2 inches tall with braille below, mounted in the same 48 to 60 inch range. The main entry floor gets a tactile star on both jambs. These signs are how a blind passenger confirms they’ve reached the right floor, and in older buildings they’re often worn, missing or on only one side.
Jamb plates are our specialty. We make them in-house with the floor number, elevator ID and colors to match your lobby.
Common mistakes
Mixed-case raised lettering (raised characters must be uppercase)
Braille beside the text instead of below it
Room signs mounted on the door itself, or too high on the wall
Glossy faces that glare under lobby lighting
Floor signs on only one jamb of an elevator entrance
New Jersey and NYC codes
Building codes in New Jersey and New York City also reference ICC A117.1, which has its own sign specifications alongside the federal ADA Standards. On any specific project, your architect or code official has the final word. We build to what your plans call for.
Need signs made?
Send us your room list, floor count or plans and we’ll quote a full sign package, with installation if you want it. Request a quote or see our ADA sign work.
This guide summarizes sections 216, 407 and 703 of the 2010 ADA Standards for Accessible Design for general information. It isn’t legal advice.